FUNCTIONING LAYOUT
 |
 |
The fireplace must e mounted with open vessel.
The water in the radiators circuit heats up, circulating in the heat exchanger pipe (A) and in the gap (B) that brushes against the entire semi-circular wall of the firebox.
The gap is realised with thick sheet steel.
Automatic combustion product by-pass
In the ignition phase, with vent open in order to ease the start of combustion, the combustion product gate valve (C) stays open in a way that the combustion products can reach the flue (D) directly and easily. When combustion is taking place, by closing the door the combustion products gate valve (C) also automatically closes. In this set-up, the combustion products are diverted before reaching the flue in a way to flow over and give up heat to the gap (B) and the heat exchanger pipe (A).
(e) heat isolation on the roof (customer’s responsibility)
(f) gate valve in closed position
(g) glass ceramic resistant to 800°C |
|
|